Loading...

ACI WRITTEN EXAM ACTUAL 2025/2026 Q&A 100% PASS

0

Course:
ACI CONCRETE

Institution:
ACI CONCRETE

ACI WRITTEN EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS The sensor of the temperature measureing device shall be submerged a minimum of ____ in - Answer -3 (75mm) The temperature measureing device shall have a capacity of measuring tempe...

Preview (2 out of 27 pages)

ACI WRITTEN EXAM ACTUAL 2025/2026 Q&A 100% PASS ACI WRITTEN EXAM ACTUAL 2025/2026 Q&A 100% PASS

After purchase, you get:

✅ Instant PDF Download
✅ Verified answer explanations
✅ Refund if not Satisfied
✅ Prepared for 2025/2026 test cycle

Document Information
Uploaded on: October 24, 2025
Last updated: October 24, 2025
Number of pages: 27
Written in: 2025/2026
Type: Exam (elaborations)
Contains: Questions & Answers
Tags: ACI WRITTEN EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS The sensor of the temperature measureing device shall be submerged a minimum of ____ in - Answer -3 (75mm) The temperature measureing device shall have a capacity of measuring temperature of freshly mixed conrcrete to +-_____ degrees F throught a range of _____ - Answer -1(.5 degrees C), 30-120 (0-50 degrees C) The temperature measuring device shall be calibrated____, or whenever there is a question of _____ - Answer -annually, accuracyNeed assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com The temp of concrete may be measured in a wheelbarrow - Answer -true the temp of concrete may be measured in a wall form - Answer -true A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temp. - Answer -false What must be done to the sample container prior to sampling the concrete - Answer -dampen (with water) what must be done to the concrete sur
Seller Information
Profile

AdelineJean

User Reviews (0)

Exam (Elaborations)

$9.00

Bundle Deal! Get all 5 docs for just $11.00

Add to Cart

100% satisfaction guarantee
Refund Upon dissatisfaction
Immediately available after purchase
Available in Both online and PDF

$9.00

| 0 sold

Add to Cart
Discover More resources
Available in a Bundle

Content Preview

ACI WRITTEN EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS The sensor of the temperature measureing device shall be submerged a minimum of ____ in - Answer -3 (75mm) The temperature measureing device shall have a capacity of measuring temperature of freshly mixed conrcrete to +-_____ degrees F throught a range of _____ - Answer -1(.5 degrees C), 30-120 (0-50 degrees C) The temperature measuring device shall be calibrated____, or whenever there is a question of _____ - Answer -annually, accuracy The temp of concrete may be measured in a wheelbarrow - Answer -true the temp of concrete may be measured in a wall form - Answer -true A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temp. - Answer -false What must be done to the sample container prior to sampling the concrete - Answer -dampen (with water) what must be done to the concrete surrounding the temp measuring device after the device has submerged - Answer -Press concrete around measuring device Need assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com How long must the temp device remain in the concrete - Answer -at least 2 minutes (but no more than 5) After temp of concrete is read, what then is required - Answer -reporting of temp the temp of concrete to be measured to the nearest ____degree F - Answer -1 (.5 degree C) According to the ASTM C1064 what is one reason to take the temp of concrete - Answer -verify conformance to a specified requirement for temp A max temp of concrete is specified in ASTM C1064 - Answer -False The sample of concrete used for temp determination must be rodded 25 times - Answer -False Sampling by this method is required when tests are to be made to determine ____ with specification requirements - Answer -compliance The method covers sampling from four types of mixers which are _____, _____, ____, and _______ - Answer -stationary mixes, paving mixers, revolving drum mixers and open top mixers The maximum allowable time between obtaining the first and final portions of a composite sample is ______ minutes - Answer -15 Portions of a composite sample shall be thoroughly remixed before beginning tests on the sample - Answer -True The maximum elapsed time allowed between obtaining the final portion of the composite sample and beginning the tests for slump, Need assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com

Wait you get upto 50% discount for the whole Bundle!

PACKAGE DEAL FOR ACI CONCRETE EXAMS ACTUAL 2025/2026

Included Documents in the bundle:

ACI CERTIFICATION: PERFORMANCE CHECKLIST ACTUAL 2025/2026 Q&A 100% PASS
ACI CERTIFICATION: PERFORMANCE CHECKLIST ACTUAL 2025/2026 Q&A 100% PASS
ACI CONCRETE- SECTION 4 ACTUAL 2025/2026 Q&A 100% PASS
ACI CONCRETE- SECTION 4 ACTUAL 2025/2026 Q&A 100% PASS
ACI WRITTEN EXAM ACTUAL 2025/2026 Q&A 100% PASS
ACI WRITTEN EXAM ACTUAL 2025/2026 Q&A 100% PASS
ACI FLATWORK EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
ACI FLATWORK EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
ACI TEST ACTUAL 2025/2026 Q&A 100% PASS
ACI TEST ACTUAL 2025/2026 Q&A 100% PASS