HVAC NATE HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS On an R-22 system, line diameters and lengths are typically specified for a vapor pressure drop that does not exceed what? - Answer -6-7PSI or 6F What is the primary purpose of u...
✅ Instant PDF Download
✅ Verified answer explanations
✅ Refund if not Satisfied
✅ Prepared for 2025/2026 test cycle
| Uploaded on: | October 27, 2025 |
| Last updated: | October 27, 2025 |
| Number of pages: | 39 |
| Written in: | 2025/2026 |
| Type: | Exam (elaborations) |
| Contains: | Questions & Answers |
| Tags: | HVAC NATE HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS On an R-22 system, line diameters and lengths are typically specified for a vapor pressure drop that does not exceed what? - Answer -6-7PSI or 6F What is the primary purpose of using flux when soldering copper or brass parts? - Answer -Prevent Oxidation The water that results from a defrost cycle of an air to air heat pump(runoff) must? - Answer -Drain off and away from the outdoor coil. |
AdelineJean
Exam (Elaborations)
Bundle Deal! Get all 7 docs for just $22.00
Add to Cart
100% satisfaction guarantee
Refund Upon dissatisfaction
Immediately available after purchase
Available in Both online and PDF
| 0 sold
HVAC NATE HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS On an R-22 system, line diameters and lengths are typically specified for a vapor pressure drop that does not exceed what? - Answer -6-7PSI or 6F What is the primary purpose of using flux when soldering copper or brass parts? - Answer -Prevent Oxidation The water that results from a defrost cycle of an air to air heat pump(runoff) must? - Answer -Drain off and away from the outdoor coil. Why must the runoff be drained off and away from the outdoor coil? - Answer -Excessive ice can build up on the bottom of the coil and can reduce capacity. What is the component that reduces sound transmission and prevents water leaks of a package heat pump installed on a roof? - Answer -Curb Gasket Why do you need to add a control for a heat pump indoor coil that is installed on a fossil fuel furnace? - Answer -So the heat pump and furnace do not operate at the same time in normal heating. What happens when you energize a hermetic refrigeration compressor and the system is in a deep vacuum? - Answer -Motor windings could become damaged. What needs to happen in order to consider an evacuation to be complete? - Answer -System should be evacuated to a vacuum of 500 Microns or Need assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com below. A system is supplied from the factory with charge for a 15 foot line set. The data plate shows the required system charge to be 5 pounds 10 ounces. The line set uses a 3/8 inch liquid line and is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigerant to be added for each added foot of refrigerant line length. How much refrigerant is needed to completely charge the system? - Answer -6lbs Where are drive slips typically installed? - Answer -On the shorter sides of rectangular duct. What is a necessary check to properly set a heat anticipator? - Answer -Heating control circuit amperage draw. A heat pump operating in normal ice free conditions maintains a certain temperature difference between the outdoor coil temperature and the surrounding outdoor ambient. What is this temperature referred to as? - Answer -Coil TD. What is the smallest refrigerant leak that an electronic leak detector should be capable of sensing? - Answer -.o5oz per year. When checking the pressures in an operating system with a manifold gauge set, will refrigerant oil in a hose will have an effect on the gauge? - Answer -No What is the absolute pressure at sea level if a gauge pressure is 35 psig? - Answer -49.7psia 100,000 BTUH output furnace. Return air temp is 65F. Supply air is 135F. What is the CFM? - Answer -1323CFM What is the best method of repair when a residential supply diffuser is Need assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com
BUNDLE FOR NATE HEAT PUMP & A/C EXAMS ACTUAL 2025/2026
Included Documents in the bundle: