Loading...

NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026

0

Course:
NATE HEAT PUMP

Institution:
NATE HEAT PUMP

NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS Which of the following factors affects a customers level of comfort? - Answer -All of the above A cooling load calculation estimates the sensible heat gain of the...

Preview (2 out of 43 pages)

NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026 NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026

After purchase, you get:

✅ Instant PDF Download
✅ Verified answer explanations
✅ Refund if not Satisfied
✅ Prepared for 2025/2026 test cycle

Document Information
Uploaded on: October 27, 2025
Last updated: October 27, 2025
Number of pages: 43
Written in: 2025/2026
Type: Exam (elaborations)
Contains: Questions & Answers
Tags: NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS Which of the following factors affects a customers level of comfort? - Answer -All of the above A cooling load calculation estimates the sensible heat gain of the structure. The cooling-only system should be within _____% of this calculated value. - Answer -+15% The maximum sensible cooling capacity of a heat pump should be within ______% of the calculated sensible heat gain of a structure with a large heating load. - Answer -+25%
Seller Information
Profile

AdelineJean

User Reviews (0)

Exam (Elaborations)

$9.50

Bundle Deal! Get all 7 docs for just $22.00

Add to Cart

100% satisfaction guarantee
Refund Upon dissatisfaction
Immediately available after purchase
Available in Both online and PDF

$9.50

| 0 sold

Add to Cart
Discover More resources
Available in a Bundle

Content Preview

NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS Which of the following factors affects a customers level of comfort? - Answer -All of the above A cooling load calculation estimates the sensible heat gain of the structure. The cooling-only system should be within _____% of this calculated value. - Answer -+15% The maximum sensible cooling capacity of a heat pump should be within ______% of the calculated sensible heat gain of a structure with a large heating load. - Answer -+25% The combined output of a heatpump and its auxiliary heat should not exceed the calculated heat loss of a home by more than ____%. - Answer -15% What amount of auxiliary electronic heat is needed when the output of a heat pump on a design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh? - Answer -3.2 kWh The three processes that transfer heat energy are conduction, convection, and _________. - Answer -Radiation Heat transfer that occurs when substances of different temperatures are in contact with each other is called _______. - Answer -conduction What effect does raising the pressure in a sealed system have on Need assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com refrigerant? - Answer -The boiling point increases What is the primary danger to people near an accidental refrigerant release or spill? - Answer -suffocation caused by the heavier refrigerant displacing oxygen in the air The maximum temperature at which refrigerant may be stored is ______ F when the container is no more than ____% full of liquid by volume.; - Answer -125 F, 80% Boiling of the refrigerant occurs in which system component? - Answer -Evaporator Why is superheat necessary in a system that utilizes hermetic compressors - Answer -It ensures that dry vapor reaches the compressor so that mechanical damage does not occur When the heat load on an evaporator increases, what is the effect on the system? - Answer -Suction pressure and discharge pressure both increase What type of energy is transferred when work is done in the condenser? - Answer -Both latent and sensible heat energy What is the primary function performed by a thermal expansion valve? - Answer -It maintains the correct superheat in the suction vapor leaving the evaporator Which component pumps refrigerant through the system and raises the vapor temperature? - Answer -compressor How are hermetic compressor motors cooled? - Answer -With suction vapor drawn from the evaporator Need assistance on Online classes, Exams & Assignments? Reach out for instant help!! Full Course Assistance, Plagiarism-free Essay Writing, Research Paper, Dissertation, Discussion Posts, etc…. Confidential & Secure services. Tutors are available for all subjects! Email now at: tutorjean01@gmail.com

Wait you get upto 50% discount for the whole Bundle!

BUNDLE FOR NATE HEAT PUMP & A/C EXAMS ACTUAL 2025/2026

Included Documents in the bundle:

NATE CORE AND NATE HEAT PUMPS ACTUAL 2025/2026 WITH VERIFIED ANSWERS
NATE CORE AND NATE HEAT PUMPS ACTUAL 2025/2026 WITH VERIFIED ANSWERS
A/C AND HEAT PUMP MIDTERM - FINAL ACTUAL 2025/2026 WITH CORRECT ANSWERS
A/C AND HEAT PUMP MIDTERM - FINAL ACTUAL 2025/2026 WITH CORRECT ANSWERS
NATE A/C AND HEAT PUMPS BASICS ACTUAL 2025/2026 Q&A
NATE A/C AND HEAT PUMPS BASICS ACTUAL 2025/2026 Q&A
NATE HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
NATE HEAT PUMP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026
NATE AIR CONDITIONING AND HEAT PUMP ACTUAL 2025/2026
HVAC NATE HEAT PUMP ACTUAL 2025/2026 CORRECTLY ANSWERED
HVAC NATE HEAT PUMP ACTUAL 2025/2026 CORRECTLY ANSWERED
NATE HEAT PUMP EXAM ACTUAL 2025/2026 WITH VERIFIED ANSWERS
NATE HEAT PUMP EXAM ACTUAL 2025/2026 WITH VERIFIED ANSWERS